Mobdus Constructor 1.6.0
In Modbus Constructor you can work with integer, long, float, double, or byte data types. Integer types may be represented as signed, unsigned, HEX or binary. The same register can be represented in various ways. For example, if there are two adjacent registers that contain long numbers, each of these registers can be given additional data fields in which their content will be represented as HEX or unsigned integer.
Data fields corresponding to your data elements (registers or discreet elements) can be arranged to your liking inside the project form window. You can specify size, color, font and caption for each field.
The discreet elements occupying a continuous addresses domain can share the same field, which makes them easier to read and saves time.
In Modbus Constructor you can setup any register data field to perform a linear transformation to convert the internal units into units of any system. For example, if a register contains pressure in mA, i.e. the device receives data from a pressure detector equipped with a current output, the resulting value can be converted to kgf/cm2 or lb/in2.
Modbus Constructor supports automatic requests for all supported functions (01, 02, 03, 04, 05, 06, 15, 16, 22, 23) with individual periods for each one.
You can setup requests to be executed via menus or dialogs. This is a convenient way of setting up control commands, changing parameters and test requests. Any project may be used for querying a device in a Master mode or simulating it in a Slave mode.
- improved performance
- misc. bugs fixed
...to analyze a Modbus RTU message? The...CAS Modbus RTU parser can analysis...a Modbus RTU message and tell...your device, what device the message came...
.../ Terminal / Protocol Analyzer / Debugger...view, analyze, and test serial ports activity....more expensive hardware protocol analyzer is required....emulator) a serial device becomes a simple...and time sensitive device a simple task....It supports data input and monitoring in...Octal, Binary and ASCII formats. It also...
...cost industry standard Modbus or NetCommander hardware...RS485 connected system or...to 16 analogue input and outputs, 16...can also be set up. The events...
...AggreGate Device Management Platform is...collect (or "aggregate") device data into a...cost-effective. Any existing device may work with...implementing AggreGate communication protocol in your own...device, or by protocol conversion via software...device drivers. For new...directly, no software/hardware protocol conversion is required....
...